SECTOR:
I= Industrial
M= Marine
R= Railway |
COOLING:
NA= Natural Air
FA= Forced Air
H2O= Water |
|
|
|
|
SECTOR
|
MAX. POWER (kVA)
|
MAX. VOLTAGE (KV)
|
|
TM
- single-phase shielded-core transformer
|
I
|
5
|
7,2
|
|
MAX. CURRENT (kA)
|
MAX. FREQUENCY
(kHz)
|
COOLING
|
APPLICATION
|
|
0,5
|
20
|
NA
|
Matching -Isolation
|
|
|
|
|
SECTOR
|
MAX. POWER (kVA)
|
MAX. VOLTAGE (KV)
|
|
TTM
- single/three-phase transformer
|
I
|
1000
|
7,2
|
|
MAX. CURRENT (kA)
|
MAX. FREQUENCY (kHz)
|
COOLING
|
APPLICATION
|
|
10
|
20
|
NA
|
Matching -Isolation
|
|
|
|
|
SECTOR
|
MAX. POWER (kVA)
|
MAX. VOLTAGE (KV)
|
|
TF
- ferrite-core transformer
|
I-M-R
|
200
|
7,2
|
|
MAX. CURRENT (kA)
|
MAX. FREQUENCY (kHz)
|
COOLING
|
APPLICATION
|
|
0,5
|
50
|
NA-FA-H2O
|
Isolation - Rectification - Conversion
|
|
|
|
|
SECTOR
|
MAX. POWER (kVA)
|
MAX. VOLTAGE (KV)
|
|
T2
- single-phase 2-winding transformer
|
I-M-R
|
1000
|
7,2
|
|
MAX. CURRENT (kA)
|
MAX. FREQUENCY (kHz)
|
COOLING
|
APPLICATION
|
|
20
|
20
|
NA-FA-H2O
|
Isolation - Rectification - Conversion
|
|
|
|
|
SECTOR
|
MAX. POWER (kVA)
|
MAX. VOLTAGE (KV)
|
|
T3
- three-phase 3-winding transformer
|
I-M-R
|
2000
|
7,2
|
|
MAX. CURRENT (kA)
|
MAX. FREQUENCY (kHz)
|
COOLING
|
APPLICATION
|
|
20
|
20
|
NA-FA-H2O
|
Isolation - Rectification - Conversion
|
|
|
|
|
SECTOR
|
MAX. POWER (kVA)
|
MAX. VOLTAGE (KV)
|
|
T5
- three-phase 5-winding transformer
|
I
|
2000
|
7,2
|
|
MAX. CURRENT (kA)
|
MAX. FREQUENCY (kHz)
|
COOLING
|
APPLICATION
|
|
20
|
20
|
NA-FA-H2O
|
Isolation - Rectification - Conversion
|
|
|
|
|
SECTOR
|
MAX. POWER (kVA)
|
MAX. VOLTAGE (KV)
|
|
T6
- three-phase 6-winding transformer
|
I
|
2000
|
7,2
|
|
MAX. CURRENT (kA)
|
MAX. FREQUENCY (kHz)
|
COOLING
|
APPLICATION
|
|
20
|
20
|
NA-FA-H2O
|
Isolation - Rectification - Conversion
|
|
|
|
|
SECTOR
|
MAX. POWER (kVA)
|
MAX. VOLTAGE (KV)
|
|
I2
- integrated single-phase 2-winding transformer
|
I-R
|
1000
|
7,2
|
|
MAX. CURRENT (kA)
|
MAX. FREQUENCY (kHz)
|
COOLING
|
APPLICATION
|
|
20
|
20
|
NA-FA
|
Inverter output
|
|
|
|
|
SECTOR
|
MAX. POWER (kVA)
|
MAX. VOLTAGE (KV)
|
|
I3
- integrated three-phase 3-winding transformer
|
I-R
|
2000
|
7,2
|
|
MAX. CURRENT (kA)
|
MAX. FREQUENCY (kHz)
|
COOLING
|
APPLICATION
|
|
20
|
20
|
NA-FA
|
Inverter output
|
|
|
|
|
SECTOR
|
MAX. POWER (kVA)
|
MAX. VOLTAGE (KV)
|
|
I5
- integrated three-phase 5-winding transformer
|
I-R
|
2000
|
7,2
|
|
MAX. CURRENT (kA)
|
MAX. FREQUENCY (kHz)
|
COOLING
|
APPLICATION
|
|
20
|
20
|
NA-FA
|
Inverter output
|
|